2381designer cover20306750 12/14 Rev. 1 Designer Series Direct Vent Gas FireplaceInstallation and Operating InstructionsModels: STLDV(N/P)SCSB, PFLD
46¹⁄₈” (1172 mm)(1/2” Drywall)or46” (1168 mm)(5/8” Drywall)23” (584 mm)(1/2” Drywall)or Adjustable to22³⁄₄” (578 mm)(5/8” Drywall)48³⁄₁₆” (1224 mm)46⁵
INSTALLATION INFORMATION2030675011Designer Series Direct Vent Gas FireplaceBEFORE YOU STARTRead this homeowner manual thoroughly and follow all
1220306750Designer Series Direct Vent Gas FireplaceFIREPLACE LOCATIONPlan for the installation of your appliance. This includes determining where the
2030675013Designer Series Direct Vent Gas FireplaceCLEARANCES TO COMBUSTIBLES MANTEL CLEARANCES NOTE: The combustible area above the facing must not p
1420306750Designer Series Direct Vent Gas FireplaceINSTALLATION PRECAUTIONSConsult local building codes before beginning the installation. The install
2030675015Designer Series Direct Vent Gas FireplaceAfter conversion to top vent conguration, the 5" (127 mm) flue pipe should be concentr
1620306750Designer Series Direct Vent Gas Fireplace**1"**1”*3"37⁷⁄₈”(962 mm)Flue PipeCenterlineto FloorFP2819vent clearance**1"*3"
2030675017Designer Series Direct Vent Gas FireplaceINSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termin
1820306750Designer Series Direct Vent Gas FireplaceVENTING INSTALLATION V XX X D E B B B C B M B AJ K F L VENT TERMINATION AIR SUPPLY INLET AREA WHE
2030675019Designer Series Direct Vent Gas FireplaceVENTING INSTALLATION HOW TO USE THE VENT GRAPHThe Vent Graph should be read in conjunction wi
220306750Designer Series Direct Vent Gas FireplaceCONTENTSImportant Safety Information ...3Code Approval ...
2020306750Designer Series Direct Vent Gas FireplaceREAR WALL VENT INSTALLATION (5" x 8" VENTING ONLY)When installed as a rear vent unit, thi
2030675021Designer Series Direct Vent Gas Fireplace6. Slide the stop over the vent pipe before connecting the horizontal run to the vent cap. Figure
2220306750Designer Series Direct Vent Gas FireplaceHORIZONTAL WITH VERTICAL RISE (THROUGH-THE-WALL) TERMINATION CONFIGURATIONSSince it is very importa
2030675023Designer Series Direct Vent Gas Fireplace• The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows
2420306750Designer Series Direct Vent Gas Fireplace1. Locate and cut the vent opening in the wall. For com-bustible walls rst frame in opening. Co
2030675025Designer Series Direct Vent Gas FireplaceInstall restrictor disc as shown in Figure 34 for vertically vented applications. Up to two (2) res
2620306750Designer Series Direct Vent Gas Fireplace12341234FP2309max elbow use AFigure 36 - Maximum Elbow Usage Example: Elbow 1 = 90° Elbow 2
2030675027Designer Series Direct Vent Gas FireplaceFP1969firestop w room aboveFigure 38 - If Area Above is a Room, Install Firestop above Framed Hole
2820306750Designer Series Direct Vent Gas FireplaceFLEX VENT INSTALLATION 1. Flexible UL1777 listed venting may be used in any venting applic
2030675029Designer Series Direct Vent Gas FireplaceD. Attaching exible venting to vertical termination assemblies.1. When using Duravent pipe, a
203067503Designer Series Direct Vent Gas Fireplace4. Never install the replace • in a recreational vehicle • where curtains, furniture, cl
3020306750Designer Series Direct Vent Gas Fireplace4" x 7" Flex PipeIf you prefer to use 4" x 7" ex pipe, you must install model
2030675031Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATION CHECK GAS TYPEUse proper gas type for the replace you are installing. If yo
3220306750Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATION NOTE : The gas line connection may be made using 1/2" rigid tubing or
2030675033Designer Series Direct Vent Gas FireplaceFP1909asignature command valvealternate view8/08CHECK GAS PRESSURE 1. Check gas type. The gas supp
3420306750Designer Series Direct Vent Gas FireplaceJUNCTION BOX WIRING1. This should be done before framing the replace. Wire the receptacle into an
2030675035Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATIONCAUTIONElectrical connections should only be performed by a qualied, lic
3620306750Designer Series Direct Vent Gas FireplaceTo Junction BoxIn FireplaceWHITEBLACKWHITEBLACKBLACKWHITEGREENConnectorPin To Contro l Box{{LightOp
2030675037Designer Series Direct Vent Gas FireplaceBLACKBLACKWHITEGREENBLACKBLACKWHITEReceptacle Junction Box120VACSpeed Control FP2685BLOTSDV blower
3820306750Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATIONCAUTIONEach clamp has a quick spring force. When reinstalling clamps, keep n
2030675039Designer Series Direct Vent Gas FireplaceLG970designer Dv rockwoolFP2841rockwoolFIREPLACE INSTALLATIONROCK WOOL PLACEMENTPlace rock wool eve
420306750Designer Series Direct Vent Gas FireplaceIMPORTANT SAFETY INFORMATION12. Do not use this replace to cook food or burn paper or other object
4020306750Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATIONLG968designer DV log 4LG967designer DV log 33. Position log #3 on the key pr
2030675041Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATIONLG969Designer DV log 55. Place log #5 on the key provided on log #4. Rest th
4220306750Designer Series Direct Vent Gas FireplaceFIREPLACE INSTALLATIONNOTE: A barrier designed to reduce the risk of burns from the hot viewing gla
2030675043Designer Series Direct Vent Gas FireplaceOPERATING INSTRUCTIONSA. This appliance is equipped with an ignition device which automatically li
4420306750Designer Series Direct Vent Gas FireplaceOPERATING INSTRUCTIONSFP1913 Switch box 8/08 Command CenterONMaster SwitchOFFFP1914 Pilot w sparker
2030675045Designer Series Direct Vent Gas FireplaceFEATURESCommand Center• Easy Access Function Operation and System Congura-tion• Operation Conrm
4620306750Designer Series Direct Vent Gas FireplaceSIGNATURE COMMAND SYSTEM OPERATIONSYSTEM CONFIGURATION/SETUPAll System conguration/setup is done o
2030675047Designer Series Direct Vent Gas FireplaceSIGNATURE COMMAND SYSTEM OPERATION Fault LED Indication Conversion Cover Missing One RED (1 tim
4820306750Designer Series Direct Vent Gas FireplaceFP2453hooded pilot flamesCLEANING AND MAINTENANCE BURNER, PILOT AND CONTROL COMPART-MENTKeep the
2030675049Designer Series Direct Vent Gas FireplaceCLEANING AND MAINTENANCE VENT SYSTEMThe replace and venting system should be inspected befo
203067505Designer Series Direct Vent Gas FireplaceINSTALLATION INFORMATIONPRODUCT SPECIFICATIONS• This appliance has been certied for use with
5020306750Designer Series Direct Vent Gas FireplaceTROUBLESHOOTING OPERATION Install batteries and/or plug in the AC board Flip the master switch (roc
2030675051Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTSFIREBOX COMPONENTSItem Description ST Qty.PF Qty.CR/CL Qty.Designer LDV Part No.1
5220306750Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTSSIGNATURE COMMAND SYSTEM11223415137161159682381LDV SCS burner parts
2030675053Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTSSIGNATURE COMMAND SYSTEMItem Description Qty. Designer Natural Designer LP1. Burne
5420306750Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTS Item Description Qty. Designer LDV1. Log #1 1 203024322. Log #2 1 203024333. Log
2030675055Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTS VENT COMPONENTSHOT12345697811100004MLDV vent parts
5620306750Designer Series Direct Vent Gas FireplaceREPLACEMENT PARTS ItemQty./Box DescriptionCurrent Duravent or VCG Part No.Old Duravent or VCG P
2030675057Designer Series Direct Vent Gas FireplaceVENTING COMPONENTSItemQty./Box DescriptionCurrent Duravent or VCG Part No.Old Duravent or VCG Pa
5820306750Designer Series Direct Vent Gas FireplaceVENTING COMPONENTS Description Model Number Horizontal Vent Termination Kits Rear Vent Hot Touc
2030675059Designer Series Direct Vent Gas FireplaceVENTING COMPONENTS Description Model Number Vertical Vent Termination Kits Vertical Vent Termin
INSTALLATION INFORMATIONFIREPLACE DIMENSIONS620306750Designer Series Direct Vent Gas FireplaceFigure 2 - STLDV (See-thru) Fireplace Dimensions3³⁄₁₆”(8
6020306750Designer Series Direct Vent Gas FireplaceVENTING COMPONENTSNOTE REGARDING VENTED PRODUCTSThis product must be installed by a licensed plumbe
2030675061Designer Series Direct Vent Gas FireplaceLIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to
6220306750Designer Series Direct Vent Gas FireplaceThis page left blank.
2030675063Designer Series Direct Vent Gas FireplaceThis page left blank.
Based on CSA P.4.1-09Based on CSA P.4.1-09Recherchez dans la brochureles caractéristique de rendementénergétique de foyer au gazÉnerguideSelon CSA P.4
INSTALLATION INFORMATIONFIREPLACE DIMENSIONS203067507Designer Series Direct Vent Gas Fireplace21”(533 mm)18¹⁄₂”(470 mm)28¹⁄₄”(718 mm)25³⁄₄”(654 mm)7⁷⁄
STLDV FRAMINGINSTALLATION INFORMATION820306750Designer Series Direct Vent Gas Fireplace48³⁄₁₆”(1224 mm)CL27³⁄₈” (695 mm)50¹⁄₁₆” (1272 mm)23" (1/2
CRLDV/CLLDV FRAMINGINSTALLATION INFORMATION203067509Designer Series Direct Vent Gas Fireplace27¹⁄₂” (699 mm)(1/2” Drywall)or27³⁄₈” (696 mm) (5/8” Dryw
Commentaires sur ces manuels