MHSC WR2500X02 Manuel du propriétaire Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
6
Windsor High Efficiency Wood Insert
30005129
Figure 5
Face Plate Assembly
ST1024
34
FACEPLATEINSTALL

Masonry
Fireplace
End of
Spring
Spring #10
Face Plate
Assembly
ST1025
Figure 6
Install Face Plate



1. A chimney connector shall not pass through an attic,
roof space, closet, floor, ceiling or similar concealed
space. Where passage through a wall or partition of
combustible constructions is desired, the installation
shall conform to CAN/CSA B365 (in Canada). In the
US, check with local building officials for require-
ments in your area.
2. It is advisable to have your masonry chimney in-
spected for deterioration such as cracks and crum-
bling mortar before you install your unit.
34
CHIMNEYLINER

6” (152 mm) Min.
Dia. Stainless
Steel Flexible
Liner
 A stain-
less steel adapter
is recommended for
fastening the stainless
steel flexible liner to
the collar.
Male or crimped end
of the adapter must
be installed inside the
flue collar. Drill flue
collar to permanently
fasten stainless steel
adapter using a mini-
mum of 3 screws.
Fasten stainless steel
chimney liner to the
stainless steel adapter
using manufactures
instructions.
ST1026
Figure 7
Chimney Liner
3. To help ensure a good draft, the top of the chimney
should be at least 3 feet (914 mm) above the point
of penetration through the roof, and be at least 2 feet
(610 mm) higher than any point of the roof within 10
feet (3 m).
4. Do not use makeshift compromises during installa-
tion.
5. Do not remove bricks or mortar from the fireplace.
Canada: This fireplace insert must be installed with
a continuous chimney liner of 6” (152 mm) minimum
diameter extending form the flue collar to the top of the
chimney. The chimney liner must conform to the class 3
requirements of CAN/ULC-S635 Standard for lining sys-
tems for existing masonry or factory-built chimneys and
vents, or CAN/ULC-S640 Standard for lining systems
for new masonry chimneys. (Fig. 7)
USA: This fireplace insert must be connected to:
1. A chimney complying with the requirements for type
HT chimneys in the Standard for Chimneys, Factory-
built, Residential type and building Heating Appli-
ance, UL103, or
2. A code-approved masonry chimney with flue liner.


Contact your local building authority for approved meth-
ods of installation.
 This fireplace insert must be connected to:
A chimney complying with the requirements for type
HT chimneys in the Standard for Chimneys, Factory-
built, Residential Type and building Heating Appliance,
Vue de la page 5